Hot Sale Boilers
GET 20%OFF √
Certification:ASME、ISO9001、CE、ISO、BV、CCC
Available fuel:Nature gas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.
Available industries:Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.
E-mail:[email protected]
Please email or call us for your inquiry
from the tubes. The furnace is constructed of brickwork and is not water-cooled. The capacity of this style of boiler is 45 000 kg/h of steam at 4820 kPa. Three-Drum Bent Tube Boiler This boiler is designed for areas where head room is limited. The space above the water level in the upper drum is steam space and both the steam outlet and
Get priceKNIGHT™ Fire Tube Boiler. Consistency in features and benefits across the KNIGHT Fire Tube Boiler family makes it easier to install and service no matter what model you choose. 6 Models from 55,000 to 285,000 Btu/hr. 95% AFUE. Up to 10:1 Turndown Ratio.
Get priceSpace-and Water-Heating Units Hydronic boilers: Single family Multifamily, per unit Water-Heating Appliances Water heaters, automatic: storage 30 to 40 gal. tank Water heater, automatic storage 50 gal. tank Water heater, automatic instantaneous: Capacity at 2 gal./minute Capacity at 4 gal./minute Capacity at 6 gal./minute
Get priceA reasonably well-insulated shell or water-tube boiler of 5 MW or more will lose between 0.3 and 0.5% of its energy to the surroundings. This may not appear to be a large amount, but it must be remembered that this is 0.3 to 0.5% of the boiler's full-load rating, and this loss will remain constant, even if the boiler is not exporting steam to
Get priceDec 14, 2020 · 56. Water substance at 70 bar and 65°C enters a boiler tube of constant inside diameter of 35 mm. The water leaves the boiler tube at 50 bar and 700 K at velocity of 150 m/s. Calculate the inlet volume flow (liters/s). From steam tables: @ 70 bar (7 Mpa) and 65°C: υ1 = 0.001017 m 3 /kg
Get pricea hot water boiler in which water or other fluid is heated and intended for operation at pressures not exceeding l60 psi or temperatures not exceeding 250 degrees Fahrenheit. (d) Electric Boiler - A power boiler or heating boiler in which the source of heat is electricity. (e) Miniature Boiler - …
Get priceMethane is burned with air in a PA Hilton boiler to produce hot water oof 55oC. The fuel is fed at a rate of 7 kg/hr at 25 C, the air enters the boiler at a rate of 130 kg/hr at 42.5oC, and the water enters the boiler at a flow rate of 1000 kg/hr at 10oC. The composition of the dry flue gas leaving the boiler at 700oC are found to be 0.9% O 2
Get priceExpert Answer Transcribed image text: 27.) A water-tube boiler has a capacity of 150,000 lb/h of steam at a pressure and temperature of 385 psig and 500°F. Feedwater enters the economizer at 250°F and leaves at 346°F. The efficiency of the boiler is 87 percent.
Get price750-94 (revised 2009) Model CB, CB-LE Packaged Boiler Manual iii 2.12 — Oil Fuel Flow: Heavy Oil 2-22 2.13 — Gas Fuel Flow 2-24 2.14 — Modulating Firing 2-24 CHAPTER 3 Waterside Care and Requirements 3-1 3.1 — Overview 3-1 3.2 — Water Requirements: Hot Water Boiler 3-2 3.2.1 — Air Removal 3-2 3.2.1.1 — Minimum Water Temperature 3-2 3.2.1.2 — Rapid Replacement of Boiler …
Get price87. Supplementary Problem A counterflow bank of boiler tubes has total area of 900 ft2 and its over-all efficiency of heat transfer is 13 Btu/hr-ft2-oF. Calculate the heat transferred if the log mean temperature difference is 1380oF. a. 16,146,000 Btu/hr c. 18,148,000 Btu/hr b. 17,147,000 Btu/hr d. 15,145,000 Btu/hr
Get price• (C) Replace the tube with a spare, if available, or plug it. o (D) Assure that the warped tube does not touch adjacent tubes and then reroll it in the header. If choice C is selected set score to 1. 30. The boiler water gage glasses should be blown down _____. o (A) when the boiler water level changes in a steaming boiler
Get price172P. 173P. Water enters the constant 130-mm inside-diameter tubes of a boiler at 7 MPa and 65°C, and leaves the tubes at 6 MPa and 450°C with a velocity of 80 m/s. Calculate the velocity of the water at the tube inlet and the inlet volume flow rate.
Get price2. BOILERS Bureau of Energy Efficiency 27 Syllabus Boilers: Types, Combustion in boilers, Performances evaluation, Analysis of losses, Feed water treatment, Blow down, Energy conservation opportunities. 2.1 Introduction A boiler is an enclosed vessel that provides a means for combustion heat to be transferred into water until it becomes heated water or steam.
Get priceA A water tube boiler has a capacity of 1000 kg/hr of steam. The factor of evaporation is 1.3 boiler rating is 200%, boiler efficiency is 65% heating surface area is 0.91 m^3 per bo.Hp, and the heating value of fuel is 18,400 Kcal/kg. the total coal available in the bunker is 50,000 kg. determine the no, of hrs to consume the available fuel.
Get priceDec 19, 2020 · 379. A water tube boiler has a capacity of 1000 kg/hr of steam. The factor of evaporation is 1.3, boiler rating is 200%, boiler efficiency is 65% and heating surface area is 0.91 m 2 per bo.Hp. and the heating value of fuel is 18,400 kCal/kg. The total coal available in the bunker is 50,000 kg.
Get priceSpace-and Water-Heating Units Hydronic boilers: Single family Multifamily, per unit Water-Heating Appliances Water heaters, automatic: storage 30 to 40 gal. tank Water heater, automatic storage 50 gal. tank Water heater, automatic instantaneous: Capacity at 2 gal./minute Capacity at 4 gal./minute Capacity at 6 gal./minute
Get priceDec 17, 2017 · [Manual Solution*] Answers: (a) -277 kJ/kg, (b) -149 kJ/kg _____ BP2-91. In a Rankine cycle, saturated liquid water at 1 bar is compressed isentropically to 150 bar. First by reheating in a boiler and then by superheating at constant pressure of 150 bar, the water substance is brought to 750K.
Get priceApr 30, 2019 · BTU stands for British Thermal Unit, and it's a measurement of thermal energy (heat). BTUh simply refers British Thermal Units per hour. For instance, if you are looking at a boiler with a rating of 80,000 BTUh, you can safely assume that the unit's gross output is 80,000 BTUs, or 80 MBH (one MBH = 1,000 BTUh).
Get priceBoiler - 13 (ME Bd. Oct. 1986) A water tube boiler has a capacity of 1000 kg/hr of steam. The factor of evaporation is 1.3, boiler rating is 200%, boiler efficiency is 5%, heating surface area is 0.91 m 2/boiler Up, and the heating value of fuel is 18,400 Kcal/kg. The total coal available in the bunker is 50,000 kg.
Get priceA water tube boiler has a capacity of 1000 kg / hr of steam . The factor of evaporation is 1.3, boiler rating is 200 %, boiler efficiency is 5 %, heating surface area is 0.91 m 2 / boiler Hp, and the heating value of fuel is 18,400 Kcal / kg .
Get priceBacked by more than 5,000 units and 150 years of experience, B&W's water-tube package and industrial boilers have an established reputation for reliability and proven performance. They are engineered to meet unique capacity, space, fuel, emissions, …
Get priceMethane is burned with air in a PA Hilton boiler to produce hot water oof 55oC. The fuel is fed at a rate of 7 kg/hr at 25 C, the air enters the boiler at a rate of 130 kg/hr at 42.5oC, and the water enters the boiler at a flow rate of 1000 kg/hr at 10oC. The composition of the dry flue gas leaving the boiler at 700oC are found to be 0.9% O 2
Get priceThis is a unit usually consisting of a drum and tubes in which the water is evaporated and the steam driven off. c) Super-heater This is a heater placed in the hottest part of the boiler that raises the temperature of the steam well beyond the saturation temperature. There are many boiler designs and not all of them have these features.
Get priceS = 105 – 80. P2. Cut-in Pressure Delta. S = 25. Factor of Evaporation. Water enters the boiler at 225°F. The boiler pressure is 100 psi and the boiler water temperature is …
Get priceExample - Time required to Heat up Water with direct Injection of Steam. The time required to heat 75 kg of water (c p = 4.2 kJ/kg o C) from temperature 20 o C to 75 o C with steam produced from a boiler with capacity 200 kW (kJ/s) can be calculated by transforming eq. 2 to. t = m c p dT / P = (75 kg) (4.2 kJ/kg o C) ((75 o C) - (20 o C
Get priceMar 17, 2015 · Steam, Boiler, and Blowdown Pressure are the same. Combustion Efficiency is the % of fuel energy that is directly added to the feedwater and not otherwise lost or used. Blowdown Rate is the % of incoming feedwater mass flow rate that leaves the boiler as a saturated liquid at boiler pressure.